Properties and Areas of Use
Tough, hard wearing flexible film, with excellent hardness, color retention.
Good chemical resistance, and excellent water resistance
Cures at low temperatures
Technical Coating Data @ 25 °C for mixed material
Finish High Gloss, Semi-Gloss or Matt
Color Range Transparent
Solids Volume 45 ± 2%
Dry Film Thickness Range 25-75 µm
Theoretical Spreading Rate 9 m² / L @ 50 microns DFT
(loss factors will apply in practice)
Surface Dry 1 hour.
Recoat Interval 6 hours minimum
10 days maximum
Complete Cure 5 days
Pot Life 6 hours
Flash Point 28°C
Shelf Life 12 months (stored in a cool dry place)
Mixing Ratio by Weight Single Pack
VOC 769 g/L
Film Thickness and Spreading Rate:
Minimum Maximum Typical
Film thickness, dry (µm) 25 75 50
Film Thickness, wet (µm) 56 167 111
Theoretical Spreading Rate (m2/L) 18 6 9
Suitable Surfaces
Steel and non ferrous metals properly prepared and blast cleaned to ISO-Sa2½
Concrete free of contamination, dust and efflorescence, and properly prepared
Wood must be abraded with sand paper No. 320 and primed with PU or polyester wood
sealer
Application Conditions
Substrate temperature should be 10°C or above for applicaƟon and during cure and a minimum of 3°C above the dew point. Adequate dry air venƟlaƟon is recommended for optimum drying.
Application Information
Thinning should only take place after the two components have been thoroughly mixed.
Brush and Roller Thin if required with 0-5% Paint Thinner Colorama TH908UE or.
Conventional Air Spraying
Thin with 5-25% Paint Thinner Colorama TH908UE, as required.
Tip size – 2.0 mm
Tip pressure – 60 psi (0.4Mpa) approximately
Airless Spraying
Thin with 0-20% Paint Thinner Colorama TH908UE, as required
Tip size – 0.58-.79 mm approximately
Tip pressure – 2100 psi (15Mpa) approximately
Cleaning Thinner
Equipment should be cleaned immediately after use with Paint Thinner Colorama TH908UE.
Drying time:
Drying times are affected by air ventilation, temperature, film thickness and number of coats.
Substrate Temp. 10° C 25° C 40° C
Surface Dry 3 h 1h. 30 min.
Through Dry 6 h 3 h 2 h
Dry to recoat, minimum 12 h 6 h 4 h
The given data serve as guideline only. The actual drying time differs according to film thickness, ventilation, humidity and underlying paint system.
Typical paint system:
FONDAL Sealer 2 x 100 µ
URETHANE Varnish 2 x 50 µ
Storage:
Keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handling:
Handle with care. Stir well before use.
Packing Size: 5 L & 18 L
Summary Safety Information
Avoid inhalation of spray mist and skin contact by the use of masks, gloves and other
personal protection. Eyes should be cautiously washed with water or proprietary wash, and
medical attention obtained. Skin should be thoroughly washed using a cleanser and soap and
water.
Product is flammable
No sparks or flames
No smoking
Reviews